 Instruction Sheet
411-78302
25MAR08 Rev. B
0.3FPC Narrow BF-L
1. 0.3mm FPC 2. Product Name 0.3FPC Narrow BF-L-1.2H 1. Scope This specification covers the Mounting Connector on the board and handling of 0.3mm pitch FPC Connector Back Flip Lock Type.
2. Description P/N -2013496- (Narrow Type) -1981515- (Long Tine Type)
3.
3. Parts name
4. FPC
4. Recommended PCB pattern and FPC Refer to customer drawings.
213-8535 3-5-8 Tyco Electronics AMP K.K. (3-5-8 Housemate Takatsu-key Kawasaki, 213-8535) This document is subject to change. Call local AMP for the latest revision. (c) Copyright 2003 by Tyco Electronics AMP K.K. All rights reserved. * : Trademark
1 of 9
Instruction Sheet
5. 5-1. 5. Mounting procedure 5-1. Mounting procedure
411-78302
This connector has adopted the form of automatic mounting and the surface mount match. Therefore, please mount on PCB with the automatic mounting machine. Then, please perform reflow soldering by the following recommended conditions.
Soldering temperature () Peak temperature 250 +5 -0
300 255 Max. 250 230 Min. 200 180 150 100 50 Pre-Heating 9030 sec
Heat 3010 sec
Recommended temperature profile of reflow soldering
5-2. 1 2 3 0.1mm
5-2. Notes at time of Connector mounting 1 Solder paste should apply the proper volume so that neither the flux nor solder advances into the core of connector. When these advance inside the connector so much, it becomes the cause of the connector performance decrease and fault. 2 Mounting to regulate and not to deform the tine part of Connector. 3 Please keep the warp of board to small, the warp may cause of defect of soldering. (Coplanarity of this connector : 0.1mm Max)
Rev. B
2 of 9
Instruction Sheet
6. FPC 6-1. FPC 1 90 1.5N
411-78302
6. FPC insertion and pull out procedure 6-1. FPC insertion procedure 1) The center of the actuator is pushed up by the tip of a finger or the fingernail, and it is rotated by 90. At this time, the actuator can be operated by small power of 1.5N or less.
2 FPC FPC
2) Insert FPC to connector. Conductor side of FPC must be bottom. Please insert FPC to become vertical for connector and reach to end of pocket of connector.
Rev. B
3 of 9
Instruction Sheet
3
411-78302
3) To be actuator closed condition by down the actuator. Please press the actuator to make it to a complete close condition at the end.
6-2. FPC 1 90 1.5N
6-2. Notes of FPC insertion 1) Please do not do the rotation operation for the actuator to exceed 90. Moreover, please do not add the load of 1.5N or more in the direction of the arrow. It causes the actuator or the connector damage.
Rev. B
4 of 9
Instruction Sheet
2
411-78302
2) Please do not lift, and do not twist the actuator. It causes the actuator or the connector damage.
3 FPC FPC FPC FPC
3) Please do not insert FPC diagonally. It causes short-circuit, contact deformation, FPC conductor flaking off, FPC conductor breaking, and FPC imperfect insertion.
Rev. B
5 of 9
Instruction Sheet
4
411-78302
4) Please confirm whether the actuator inclines remarkably after it locks. (Confirmation of imperfect lock)
6-3. FPC 1 90
6-1. FPC pull out procedure 1) The center of the actuator is pushed up by the tip of a finger or the fingernail, and it is rotated by 90.
2 FPC
2 Please pull out FPC straight to the connector vertically.
Rev. B
6 of 9
Instruction Sheet
6-4. FPC 1 90 50 90 6-4. Notes of FPC pull out
411-78302
1) Please do not do the rotation operation for the actuator to exceed 90. The actuator rotates naturally up to 90 when lifting up to 50. Please make it to the standard of the operating procedure.
2 FPC
2) Please do not pull out FPC diagonally and while twisted.
Rev. B
7 of 9
Instruction Sheet
7. 1 FPC FPC
411-78302
7. Other notes 1) Please pull out FPC at the actuator open condition. When an impossible pulling out is done, it causes the FPC conductor damage and the contact performance decrease.
2
2Please do not use a sharp tool (tweezers and screwdriver, etc.) to operate the actuator.
3 FPC FPC
3) Please do not give the load to FPC inserted in the connector. It causes the FPC disconnection, damage, and the connector performance decrease.
4
4) Please the connector mounted on PCB must not have the load. It causes the soldering part damage and the connector performance decrease.
5 FPC
5) Please do not solder the connector that inserted FPC.
6 FPC
6) Please do not insert the one that is not application FPC in the connector.
7 0.3N
7) Please do not give the outside power of 0.3N or more to the connector unit.
8
8) Please do not touch except connector tine the solder gauntlet when you do hand soldering. Moreover, please supply neither solder nor flux in excess.
Rev. B
8 of 9
Instruction Sheet
8. 1 8. Notes in storage of the connector
411-78302
1) Please avoid it from dust, oil, and water.
2
2) Please avoid direct sunlight. It causes the trouble of the packing materials deformation etc.
3 35 75%RH 3
3) Please store it under the following recommended conditions. Please confirm the performance before using the connector when it is stored outside this condition. (In this case, we will recommend inquiring of our company.) Recommended connector storage condition Temperature 35 MAX. Humidity 75%RH MAX. (No condensation) Period Less than three months
Rev. B
9 of 9


▲Up To Search▲   

 
Price & Availability of 1-2013496-6

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X